Manual No. 016-0159-831 37
Console Programming and Calibration
Entering Data in the Data Lock Mode
1. Press the button of the variable to be edited.
2. Press ENTER. A message prompting for the data-lock code will appear.
3. Enter the data-lock code. If the code is correct, E will appear on the display.
4. Enter the data to be changed as usual.
Clear the Data-Lock Code
The Data-Lock feature may be disabled so that a data-lock code is not required in one of two ways. The code
can be changed to 0 as outlined in the “Change the Data Lock Code” on page 36, or the console can be reset,
clearing the data-lock code from the system.
Important: All calibration values entered into the SCS 450 console will be lost and must be
reprogrammed.
To reset the console:
1. Turn the POWER ON/OFF switch to the OFF position.
2. Press CE and hold while turning the POWER ON/OFF switch to the ON position.
Decimal Shift Feature
Important: When entering data for Rate 1 Cal and Rate 2 Cal, remember that 2 GPA [20 lit/ha] is entered
as 2.0 [20.0] when the decimal is unshifted, but is entered as 2.00 [20.00] when shifted.
Important: When shifting or unshifting the decimal place, recheck all calibration values to verify they are
correct.
The Decimal Shift feature is used to increase the system’s accuracy at low application rates. The following
table illustrates how shifting the decimal point can increase the system’s accuracy.
US Metric Turf
Unshifted Shift Unshifted Shift Unshifted Shift
Rate Display 000.0 00.00 0000 000.0 00.00 00.00
Rate Cal 000.0 00.00 0000 000.0 00.00 00.00
Tank Volume 0000 000.0 0000 000.0 000.0 000.0
Total Area 000.0 000.0 000.0 000.0 0000 0000
Total Volume 0000 000.0 0000 000.0 000.0 000.0
Field Area 000.0 000.0 000.0 000.0 0000 0000
Field Volume 0000 000.0 0000 000.0 000.0 000.0
Vol/Minute 0000 000.0 0000 000.0 000.0 000.0
Area/Hour 000.0 000.0 000.0 000.0 0000 0000
Rate +/- 000.0 00.00 0000 000.0 00.00 00.00
Low Tank Level 0000 000.0 0000 000.0 000.0 000.0
Low Vol/Min 0000 000.0 0000 000.0 000.0 000.0

Table of Contents

Other manuals for Raven SCS 450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven SCS 450 and is the answer not in the manual?

Raven SCS 450 Specifications

General IconGeneral
BrandRaven
ModelSCS 450
CategoryControl Systems
LanguageEnglish

Related product manuals