24
14) OFF RATE PERCENT 30
Used to set the percent of off target value. Alarm sounds when the actual rate is off from the target
rate by a specified percent. The off target value is preset to 30%, but may be changed to a different
number.
a) Display will show
OFF RATE PERCENT 30
.
Press
.
b) Display will show
OFF RATE PERCENT E
.
Enter new off rate percent and press
.
c) Momentarily depress to advance to HIGH PWM OFFSET 253.
NOTE: Some options within the DATA MENU LISTINGS may be unavailable if certain
features are on or active. The options affected are:
CONSOLE DATA PRINTOUT: Console Data Printout will not be available when DATA
LOGGER is ON or when GPS functions are active.
GPS OPTIONS: GPS options will not be available when DATA LOGGER is ON.
DATA LOGGER: DATA LOGGER will not be available when GPS functions are active.
b) Display will show
DATA LOG OFF
.
c) Depressing momentarily changes the display between DATA LOG OFF and
ON
.
A value of
OFF
means DATA LOGGER is disabled; a value of
ON means DATA LOGGER
is enabled.
13) PRESSURE CALIBRATION OF THE PRESSURE TRANSDUCER
Used to set the zero point of the pressure transducer for pressure display.
a) Display will show PRESS ENTER TO CAL PRESSURE. Press .
b) Display will show ENTER SYSTEM PRESSURE.
c) Enter actual system pressure and press .
d) Momentarily depress to advance to OFF RATE PERCENT 30.
d) Momentarily depress to advance to PRESSURE CALIBRATION.
12) DATA LOGGER ON/OFF
a) The DATA LOGGER uses the communications strings listed in Appendix 9 to pass data
out through the serial port. The data is sent at a set time interval or a set distance traveled,
as determined by the values entered in the DATA LOGGER TRIGGER VALUE and DATA
LOGGER TRIGGER UNITS. Upon each trigger, the Actual Rate string, Data Strings 1,
2, and 3, and the Time/date string are sent, in that order. When a Console calibration value
is changed, the Console will automatically send out the Cal 1, 2, and 3 strings. When a
Console switch is changed, the Data 1, 2, 3, Time/Date, and Cal 1, 2, 3 strings will be sent
by the Console. The Data, (with Time/Date string included) and Cal strings can also be
requested by the data logger using the request strings shown in Appendix 9.