8. CONTROL VALVE DELAY
Depress until DATA display flashes. The first digit, ( X 0 0 0 ), is the
Control Valve delay digit. This feature allows the user to set a delay between
the time the booms are turned ON and when the Console begins to control the flow
rate. A value of 1-9 means a delay of 1-9 seconds respectively. A value of 0
means no delay. This delay is active if the time between turning OFF and turning
ON the booms is less than 30 seconds.
7. AUTOMATIC RATE +/-
This feature sets the increment at which flow is increased or decreased
in RATE 1 or RATE 2 operation. Enter rate change value by depressing key
labelled
until DATA display flashes. To enter a value depress ,
then the increment value, and
.
EXAMPLE: If rate is to change by "1":
Enter a value of 1 for RATE +/-. When in RATE 1 or RATE 2, each time the
INC/DEC switch is positioned to INC the RATE CAL for that rate will
increase by "1". Likewise, when positioned to DEC the RATE CAL will
decrease by "1".
10. SEQUENCE TO CHANGE DATA-LOCK
1) Depress for 5 seconds, OLD CODE message will appear.
2) Enter 4 digit code within 15 seconds
and .
NEW CODE message will appear. Enter 4 digit code within 15 seconds.
EXAMPLE: For 1582, depress
and .
9. SEQUENCE TO ACTIVATE DATA-LOCK
1) Depress for 5 seconds, NEW CODE message will appear.
2) Enter 4 digit code within 15 seconds.
EXAMPLE: For 1058, depress
and .