EasyManua.ls Logo

Raven SCS 660 - Wheel Drive Speed Sensor Installation

Raven SCS 660
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
APPENDIX 5
VERIFICATION OF SPREADER CONSTANT
To verify and refine the Spreader Constant, perform the following procedure (after
completing INITIAL CONSOLE PROGRAMMING):
1) Weigh loaded truck and note weight.
2) Enter the Product Density in lbs/cu.ft. [grams/liter] into key labelled
3) Enter a "0" into the key labelled
4) With the rate switch in the MAN position, unload a portion of the load by
positioning the boom switch to ON.
5) Determine the actual weight unloaded by re-weighing the truck.
6) Compare to the TOTAL VOLUME displayed by the Console.
7) Perform the following calculation to correct the Spreader Constant if desired:
Corrected Spreader Constant = old Spreader Constant x TOTAL VOLUME
actual weight unloaded
EXAMPLE: old Spreader Constant = 228 [797]
TOTAL VOLUME amount = 2000 lbs [4400 kg]
actual weight unloaded = 1950 lbs [4290 kg]
English (US):
Corrected Spreader Constant (1 lb) = 228 x 2000 = 234
1950
Metric (SI):
Corrected Spreader Constant (1 kg) = [797] x [4400] = [817]
[4290]
This is the new Spreader Constant. Repeat this procedure until the weight of the
metered material equals the TOTAL VOLUME value.

Other manuals for Raven SCS 660

Related product manuals