CHAPTER 14
148 Viper/Viper 4+ Installation & Operation Manual
Active Link - Select the desired node.
Advance Method - Select Auto Advance and refine the settings based on preferences.
Bin Level Sensor - Advances to next node in the chain when the bin level sensor low level triggers.
Tank Empty - Advances to the next node in the chain when the tank is empty.
Low Tank - Advance to the next node in the chain when the low tank sensor triggers.
Activation Upon Completion
Shutdown Chain - Will turn all nodes in the chain off when the last bin is complete. The chain will go into
cleanout ready mode.
Start Cleanout - Will turn all of the nodes to auto with each having a fraction of the target rate for each bin. For
example, a two bin chain will apply 50% out of each bin.
Delayed Chain Shutdown - Will leave the last node running for the set time (in seconds) and then turn all nodes
off or advance to the next link.
NOTE: If the machine was reloaded after chain configuration is complete, reset the chain to the first bin in
the chain.