Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
46
Bit 3
No high reflection
High reflection Abnormal
Bit 4
External AD mode=off
External AD mode=on
Bit 5
Power Correction Mode=off
Power Correction Mode=on
Bit 6
Normal
Sub-controlling communication
abnormal
Bit 7
Normal
Sub-module abnormal
Bit 8
Guidelaser=off
Guidelaser=on
Bit 9
The laser is not ready
The laser is ready
Bit 10
QCW mode=off
QCW mode=on
Bit 11
Module Main Power=off
Module Main Power=on
Bit 12
Modulation mode=off
Modulation mode=on
Bit 13
Normal
Leakage sensors 1 leaking
Bit 14
Normal
Leakage sensors 2 leaking
Bit 15
No laser
Laser is power on
Bit 16
Gate mode=off
Gate mode=on
Bit 17
AC input normal
AC input abnormal
Bit 18
External Emission control=off
External Emission control=on
Bit 19
Normal
Laser fault
Bit 20
Slow up slow down mode off
Slow up slow down mode on
Bit 21
A laser operates in ON" mode
A laser operates in REM" mode
Bit 22
Wave mode off

Table of Contents