Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
45
RBT
Read Board Temperature
Send: RBT\r
Return: RBT:36.6\r
RPW
Read Pulse Width (ms)
Send: RPW\r
Return: RPW:5.5\r
(pulse width is 5.5ms)
RCT
Read Laser Temperature
Send: RCT\r
Return: RCT:34.5\r
PERR
Reset Errors
Send: PERR\r
Return: PERR\r
SUT
Set Up Time (ms)
Send: SUT 50\r
Return: SUT:50\r
SDT
Set Down Time (ms)
Send: SDT 50\r
Return: SDT:50\r
RUT
Read Up Time (ms)
Send: RUT \r
Return: RUT:50\r
RDT
Read Down Time (ms)
Send: RDT \r
Return: RDT:50\r
PSRT
Program Start
Send: PSRT 1\r
Return: PSRT:1\r
PSTP
Program Stop
Send: PSTP\r
Return: PSTP\r
ECM
Enable Calibration Mode
Power linear correction mode (in this mode, the
external analog is corrected and output after
filtering, so the response time of AD analog is
larger than that of through mode)
Send: ECM \r
Return: ECM\r
DCM
Disable Calibration Mode
(AD analog response time is less than 100 us in this
mode)
Send: DCM\r
Return: DCM\r
Others
Command error
Send: BGM\r
Return: Command Err!\r
STA
Read device status
Read the product status. A return value of 32-Bit
digital information. The meaning of each Bit is as
follows (undefined or reserved Bit negligible):
Send: STA
Return: STA:4100
returned value 4100(Decimal) can be
converted to 0 x1004 (hexadecimal), and
then converted to binary to see that Bits2
and 12 have been set. The laser enable is
on and the modulation mode is enabled
Bit 0
Normal operation
Authorization time
Bit 1
Normal
Temperature too high
Bit 2
Emission Off
Emission On or in preparation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raycus RFL-3000/3000-ABP and is the answer not in the manual?

Raycus RFL-3000/3000-ABP Specifications

General IconGeneral
BrandRaycus
ModelRFL-3000/3000-ABP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals