8282
ITALIANO
VEDLIGEHOLDELSESPROGRAM OG KONTROLLER
ADVARSEL!
B
RUG ALTID SPECIALISERET PERSONALE TIL ENHVER FORM FOR VEDLIGEHOLDELSE, REVISION ELLER REPARATION ELLER RET
HENVENDELSE TIL ET AUTORISERET VÆRKSTED.
PROGRAM
SKAL UDFØRES HVER … TIMER
8 40 150 500
1 KONTROL AF BATTERIVÆSKE X
2 KONTROL AF SUGEMOTORENS KULS SLIDTILSTAND X
3 KONTROL AF BØRSTEMOTORENS KULS SLIDTILSTAND X
4 RENGØR FILTRET OG SNAVSEVANDSTANKEN X
5 FJERN AFLJERINGER AF URENHEDER I UDTØMNINGSSLANGEN X
6
KONTROLLER GULVVISKERENS GUMMIBLADE FOR SLID. BERØRIN-
GSKANTERNE SKAL VÆRE HELE. HVIS DETTE IKKE ER TILFÆLDET,
SKAL DE UDSKIFTES.
X
7 KONTROLLER BØRSTENS SLID X
8 UDSKIFT BØRSTEN X
FEJLSØGNING
FEJL ÅRSAG AFHJÆLPNING
M
ASKINEN STARTER IKKE BATTERIERNE ER AFLADEDE
KONTROLLER BATTERIERNES OPLADNING, GENOPLAD DEM HVIS
DET KRÆVES
BATTERIERNE ER IKKE TILSLUTTET
TILSLUT BATTERIE RNE (SOM VIST PÅ FIGUREN OVER BATTERITILSLUTNING )
AFBRUDT VEKSELSTRØMSKABEL PÅ 230V.
(FOR MASKINER MED VEKSELSTRØMSFORSYNING)
TILSLUT KABLET TIL ELNETTET
SIKRING PÅ 3A SPRUNGET PÅ DEN ELEKTRONISKE STYRING
KONTROLLER OG UDSKIFT HVIS DET KRÆVES (FIG.3 - POS.5)
NØGLEN TIL TÆNDINGSKONTAKTEN ER IKKE DREJET I POSITION ”1”
DREJ NØGLEN I DEN NÆVNTE POSITION
GULVVISKEREN TØRRER IKKE GULVET PERFEKT.
AFBRUDT SUGESLANGE PÅ GULVVISKER TILSLUT SLANGEN IGEN
T
ILSTOPPET SUGESLANGE TAG SLANGEN AF OG RENGØR DEN
ET FREMMEDLEGEME HAR SAT SIG FAST I GULVVISKEREN.FJERN FREMMEDLEGEMET
FORRINGET SUGNING FJERN LÆKAGEN
TÆTNINGERNE TIL SUGESLANGE OG SUGEMOTOR UNDER
SNAVSEVANDSTANKEN ER BESKADIGEDE
UDSKIFT TÆTNINGEN/ERNE
G
ULVVISKERENS GUMMIBLADE ER SLIDTE VEND ELLER UDSKIFT GUMMIBLADENE
GULVVASKE/TØRREMASKINEN SPRØJTER VAND UD GENNEM ÅBNIN-
GER I PLADERNE .
GULVVISKEREN ER IKKE MONTERET OG RE-
GULERET KORREKT
MONTER GULVVISKEREN KORREKT OG REGULER DEN (SE
“KLARGØRING AF GULVVASKE/TØRREMASKINE – MONTERING
OG/ELLER REGULERING AF GULVVISKER”)
R
ENGØRINGSMIDDELOPLØSNINGEN LØBER IKKE NED, ELLER
DER LØBER KUN LIDT NED PÅ BØRSTERNE.
VANDTILFØRSELSSLANGEN PÅ BØRSTEN ER TILSTOPPET
RENGØR SLANGEN
DEFEKT ELLER SNAVSET MAGNETVENTIL RENGØR OG/ELLER UDSKIFT MAGNETVENTILEN
T
ILSTOPPET ELLER BESKADIGET FILTER RENGØR FILTRET ELLER UDSKIFT DET
M
ASKINEN RENGØR IKKE ORDENTLIGT.FULDSTÆNDIG SLIDT BØRSTE UDSKIFT
IKKE EGNET RENGØRINGSMIDDELOPLØSNING UDSKIFT RENGØRINGSMIDDELOPLØSNINGEN
B
ØRSTE IKKE EGNET TIL GULVTYPEN ANVEND EGNEDE BØRSTERTYPER
F
OR HØJ ARBEJDSHASTIGHED SÆT FARTEN NED
SUGEMOTOREN STARTER IKKE.
BATTERIERNE ER IKKE TILSLTUTTET TILSLUT BATTERIERNE
SLIDTE SUGEMOTORKUL KONTROLLER OG/ELLER UDSKIFT
SUGEMOTOR IKKE TILSLUTTET ELLER BESKADIGET
KONTROLLER FORBINDELSEN ELLER UDSKIFT MOTOREN
SPRUNGET SIKRING KONTROLLER OG/ELLER UDSKIFT
BØRSTEN DREJER IKKE
BATTERIERNE ER IKKE TILSLTUTTET TILSLUT BATTERIERNE
SLIDTE MOTORKUL KONTROLLER OG/ELLER UDSKIFT
SUGEMOTOR IKKE TILSLUTTET ELLER BESKADIGET
KONTROLLER FORBINDELSEN ELLER UDSKIFT MOTOREN
DANSK