BlackMax – Installation and Operation Manual
Page 20 of 36
Issue date: 24/11/2023. Version 13.0
To c o n v e r t t h e g e n e r a t o r p o r t t o a s m a r t l o a d o u t p u t ( d i s a b l i n g g e n e r a t o r f u n c t i o n a l i t y ), navigate to the SmartLoad Setting panel
and adjust the Smart Load Setup dropdown to read "Micro Inv Input".
There are some simple parameters to tune the AC-coupled renewables input port to your customer's requirements:
Micro Inv Input OFF:
Microinverter or grid-tied inverter shuts down when battery SOC exceeds this set value.
Micro Inv Input ON:
Microinverter or grid-tied inverter starts working when battery SOC is lower than this set value.
AC Couple Fre High:
If "Micro Inv input" is chosen, microinverter output power decreases linearly as battery SOC approaches this set value (OFF).
When battery SOC equals the set value (OFF), system frequency becomes the set value (AC couple Fre high), and the
Microinverter stops working.
Stops exporting power produced by the microinverter to the grid.
MI Export to Grid Cutoff
Enabling this setting allows you to adjust the level of export to the grid when the batteries are full from the renewable AC
Source.
NOTE
: Changes to the BlackMax settings must be done by a trained/qualified person. If in doubt, contact RedEarth Support