CONNECT-OWS Installation Guidelines
70-00200-02-00 Proprietary Redline Communications © 2014 Page 11 of 70 December 3, 2014
Attention au personnel du service
Ne pas installer les produits Redline près n'importe quel type de ligne électrique. Si votre
antenne ou du matériel connexe entrer en contact avec des lignes électriques, des
blessures graves ou la mort pourraient en résulter!
Radio Frequency Safety / Sécurité des Fréquences Radio
The installer of this radio equipment must ensure that the antenna is located or pointed
such that the antenna does not emit RF fields in excess of the general population limits
as defined by:
FCC CFR 47, Part 2.1091
http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-sec2-
1091.pdf
FCC OET Bulletin 65, Radio frequency radiation exposure evaluation for fixed
devices
http://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65
/oet65c.pdf
Health Canada limits for the general population; consult Safety Code 6, obtainable
from Health Canada’s website:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php
Santé Canada limite pour la population générale; consulter le Code de sécurité 6,
disponible sur le site Web de Santé Canada:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-fra.php .
Personal Safety
WARNING: HOT SURFACE. DO NOT TOUCH.
The Connect-OWS System is rated for operation at extreme ambient temperatures.
When operating in high temperature conditions, the chassis surface area can be higher
than the ambient temperature and personal thermal protection should be employed for
any maintenance or inspection activity.
Electrical Safety
The equipment meets the requirements for class I EN 60950-1 (protection against
electric shock).
All external circuits are TNV-1 (as defined in EN 60950-1).
All equipment must be grounded before the power cable is connected.
For electrical safety the DC power supply shall have reinforced insulation to the
mains supply.
Electrical Safety Compliance / Conformité à la Sécurité Electrique
The CONNECT system hardware has been tested for compliance to the electrical safety
specifications listed in the following table.