EasyManua.ls Logo

Redline Connect Series - Serial Interface Ports (DATA 1 & DATA 2); Ethernet Ports (ETH 1 & ETH 2); Table 6: Features - Pinout for Data1; Data 2 Port 232;485; Table 7: Features - DATA Port Leds

Redline Connect Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONNECT-OWS Installation Guidelines
70-00200-02-00 Proprietary Redline Communications © 2014 Page 18 of 70 December 3, 2014
Figure 5: Description - Connect-OWS DATA 1/2 and CON Port Pin Assignment
Serial Interface Ports (DATA 1 & DATA 2)
The DATA 1 and DATA 2 ports (RJ-45 socket) are serial interface ports.
The following table lists the pinout for the DATA 1 and DATA 2 ports.
Pin
Description
232
485 HD1
485 HD2
485 FD1
485 FD2
1
RI
-
-
-
-
2
DCD
-
-
-
-
3
DTR
-
-
-
-
4
GND
GND
GND
GND
GND
5
RxD
D+
-
Tx
Rx
6
TxD
-
D+
Rx
Tx
7
CTS
D-
-
Tx
Rx
8
RTS
-
D-
Rx
Tx
Pin
Description
Active
On
Gateway active - no data flow
Blink
Gateway active - data flow detected
Off
Gateway not active
RS-485
On
RS-485 mode
Off
RS-232 mode
Ethernet Ports (ETH 1 & ETH 2)
The ETH 1 and ETH 2 ports (RJ-45 socket) are 10/100Base-T Ethernet interface ports
for customer use.
Figure 6: Description - Connect-OWS ETH 1 and ETH 2 Port Pin Assignment