CONNECT-OWS Installation Guidelines
70-00200-02-00 Proprietary Redline Communications © 2014 Page 45 of 70 December 3, 2014
4.2 Install Outdoor Equipment
4.2.1 Install Connect-OWS on Mast
The following figure shows a correctly installed Connect-OWS terminal mounted on a
mast. The final mounting height, direction and tilt must conform to the site survey
information for this site.
: Do not install the outdoor terminal equipment during adverse weather
conditions when the threat of a lightning strike is possible.
Figure 35: Installation: Connect-OW Equipment Mounted with Cabling
Hoist Equipment to Mounting Location
For safety, it is recommended to use a hoisting device to raise the Connect-OWS to the
mounting location on the tower or mast. When at the location, secure the device against
displacement by wind. The device should remain tethered until it is securely mounted to
minimize the risk to employees working below this level.
Important: Do not use the Ethernet cable to hoist the terminal. If the Ethernet cable has
been connected and weatherproofed, create the service loop and securely attach cable
to the mounting bracket to avoid any strain on the Ethernet port connection during