EasyManua.ls Logo

Renishaw ATOM - User Manual

Renishaw ATOM
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
#renishaw
www.renishaw.com/atomdownloads
Image here if required
Installation guide
M-9693-9723-07-A
ATOM
linear encoder system

Questions and Answers

  • C
    Christina OsborneSep 1, 2025
    How to resolve non-repeatable reference mark on Renishaw Media Converter?
    • M
      Michele PatelSep 1, 2025
      The reference mark may not be repeatable because only the chosen reference mark that has been used in the calibration sequence is repeatable; other reference marks may not be phased. Ensure you are using the reference mark that has been calibrated for referencing your system. The readhead bracket must be stable and not allow any mechanical movement of the readhead. Check any unused reference marks have been deselected. Clean the scale and readhead optical window and check for damage, then recalibrate the system over the chosen reference mark.
  • E
    Edward CampbellAug 31, 2025
    What causes the LED on the Renishaw ATOM Media Converter readhead to appear Purple?
    • M
      Mary KellyAug 31, 2025
      The LED on the Renishaw Media Converter readhead appears purple because blue and red are combined, AGC is switched on, and the signal level is less than 50%. Check the readhead optical window and scale are clean and free from contamination.
  • E
    edward90Aug 30, 2025
    Why is the LED on the Renishaw Media Converter readhead appearing white with flashes of other colours?
    • K
      kendra80Aug 30, 2025
      The LED on the Renishaw Media Converter readhead appears white with flashes of other colors because AGC is switched on and the signal level is less than 70%. Check the readhead optical window and scale are clean and free from contamination.
  • D
    Daniel MedinaAug 29, 2025
    How to fix multiple reference marks output on Renishaw ATOM Media Converter?
    • C
      connie25Aug 29, 2025
      If you're getting multiple reference mark outputs on your Renishaw Media Converter, it might be because unused reference marks haven't been deselected or the FPC is damaged. Deselect all unused reference marks, as only the calibrated reference mark will be repeatable. Also, check the alignment of deselection stickers and replace the damaged FPC if applicable.
  • J
    John MillerAug 28, 2025
    Why is the LED on the Renishaw ATOM Media Converter readhead flashing Red or Blank over the reference mark?
    • C
      Crystal SchmittAug 28, 2025
      The LED may flash red or blank over the reference mark because the reference mark is not phased. Ensure you are using the reference mark that has been calibrated for referencing your system, as only this reference mark will be guaranteed to remain phased. Clean the scale and readhead optical window and check for scratches, then recalibrate the system over the chosen reference mark.
  • S
    Stephanie MercerAug 27, 2025
    Why is the LED on the Renishaw ATOM readhead double flashing Blue even after moving it past the reference mark several times?
    • K
      Kelli JohnsonAug 27, 2025
      The LED on the Renishaw Media Converter readhead may be double flashing blue because the readhead isn't detecting a reference mark. Make sure you move the readhead past your chosen reference mark several times. Also, check the scale/readhead orientation, alignment, and ensure the readhead optical window and scale are clean. Verify that the readhead variant is the correct type for the chosen scale.
  • L
    laura30Aug 27, 2025
    What to do if the LED on Renishaw Media Converter readhead is Blank?
    • D
      Dalton JohnstonAug 27, 2025
      If the LED on your Renishaw Media Converter readhead is blank, it indicates a power issue. Ensure 5 V is supplied to the readhead. For cable variants, verify the correct wiring of the connector, noting that analogue and digital systems have different pin-outs. If you're using Ti, Ri, or cabled ACi interfaces, check that the interboard connector is properly seated and in the correct orientation. For FPC variants, confirm correct insertion and orientation of the FPC cable.
  • R
    Richard PattonAug 25, 2025
    Why is the LED on my Renishaw ATOM Media Converter readhead Red and how can I get a Green LED?
    • M
      mburtonAug 26, 2025
      The LED on the Renishaw Media Converter readhead might be red because the signal strength is less than 50%. To fix this: * Check that the readhead optical window and scale are clean and free from contamination. * Check the scale and readhead orientation. * Ensure that the readhead variant is the correct type for the chosen scale.
  • L
    Lori RodriguezAug 25, 2025
    What to do if I cannot initiate the calibration routine on Renishaw ATOM?
    • J
      Joshua HendersonAug 25, 2025
      If you cannot initiate the calibration routine, and you're not using an interface with a CAL button, ensure the correct pin is being shorted to 0 V for less than 2 seconds. Also, verify that the signal size is greater than 70% before starting the calibration.

Summary

ATOM System Installation Overview

Installation Process Flow

Provides an overview of scale mounting, system connection, and alignment.

RTLF;RKLF Tape Scale Installation

RTLF Installation Drawing Details

Detailed drawing and dimensions for RTLF tape scale installation.

RKLF Tape Scale Installation Drawing

RTLF;RKLF Application Methods

RTLF;RKLF Application (Any Length)

RCLC Glass Spar Scale Installation

RCLC Installation Drawing Details

Detailed drawing and dimensions for RCLC glass spar scale installation.

System Connection Methods

Readhead and Interface Connections

Details connecting readheads to interfaces or customer electronics.

ACi Interface (FPC Variant)

FPC Variant Details and Connection

Covers FPC variant, shielding, mounting, output, and connection.

Ri Interface: Connecting the Readhead

Ti Interface: Connecting the Readhead

Readhead Mounting and Alignment

Methods and Brackets

Overview of tools, methods, and bracket types for alignment.

Shim Kit for Rideheight Adjustment

Shim Kit Components and Use

Lists parts and describes shims for rideheight adjustment.

Dummy Kit for Alignment

Dummy Kit Components and Use

Lists parts and describes the dummy head for alignment.

Accurate Bracket and Feeler Gauge Method

Signal Amplitude Adjustment Method

Calibration Overview

System Calibration Procedure

Incremental Signal Calibration

Procedure for calibrating incremental signals.

Reference Mark Phasing

Manual Calibration Exit

Factory Defaults and AGC Control

Restoring Defaults and Switching AGC

Procedures for restoring defaults and controlling AGC.

LED Diagnostics

Readhead and Ti Interface LEDs

Explains LED indications for readhead and Ti interface status.

Troubleshooting Guide

Readhead LED and Signal Issues

Diagnoses issues with readhead LEDs and signal strength.

Troubleshooting Guide (Continued)

ATOM Readhead Dimensions

FPC Readhead Dimensions

Output Signal Pin Assignments

Speed Specifications (20 µm and 40 µm)

Output Signal Pin Assignments (Digital;Analogue)

Speed Specifications (Outputs)

Output Signal Pin Assignments (Ti Interface)

Electrical Connections and Signal Handling

Analogue Output Signal Specifications

Digital Output Signal Specifications

Alarm Output Specifications

General Specifications Overview

Scale Specifications

RKLF Scale Specifications

Renishaw ATOM Specifications

General IconGeneral
BrandRenishaw
ModelATOM
CategoryMedia Converter
LanguageEnglish

Related product manuals