OMP40-2 installation guide
4.4
Trigger Logic
> 5 s
1
2
3
Key to the symbols
LED short flash
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
Deflect the stylus for more than
4 seconds to move to the next menu.
To exit, leave the stylus untouched for
more than 20 seconds.
LED check
3
Battery status
Battery good
or
Battery low
Changing the probe settings
Insert the batteries or, if they have already been
installed, remove them for five seconds and then
refit them.
Following the LED check, immediately deflect the
stylus and hold it deflected until five red flashes
have been observed (if the battery power is low,
each red flash will be followed by a blue flash).
Keep the stylus deflected until the “Switch-off
method” setting is displayed, then release it. The
probe is now in configuration mode and Trigger
Logic™ is activated.
CAUTION: Do not remove the batteries whilst
in configuration mode. To exit, leave the stylus
untouched for more than 20 seconds.
Enhanced trigger filter
Off
0 ms
On
10 ms
Switch-off method
Optical off
Short
timeout
12 s
Medium
timeout
33 s
Long
timeout
134 s
Optical transmission method
Legacy
(start filter off)
Legacy
(start filter on)
Modulated
PROBE 1
Modulated
PROBE 2
Modulated
PROBE 3