7.1
OMP40-2LS system
Introduction
The OMP40-2LS probe has a reduced switch-on
range when compared to an OMP40-2 probe.
Performance envelope with an
OMM-2 / OMI-2T / OMI-2H / OMI-2
(modulated transmission)
Typical plot at 20 °C (68 °F) 360° transmission around probe axis in m (ft)
OMP40-2LS
OMM-2
OMI-2T
OMI-2H
OMI-2
60°
45°
45°
15°
30°
30°
15°
60°
60°
45°
45°
15°
30°
30°
15°
60°
75°
4 (13.1)
3 (9.8)
2 (6.5)
5 (16.4)
4 (13.1)
3 (9.8)
2 (6.5)
1 (3.3)
5 (16.4)
75°
75°
75°
Optical centre line
Switch-on / switch-off
Operating – standard power mode
Operating – low power mode
1 (3.3)