3 609 929 B45/2013-06 |
CS351/CC-CS351 Bosch Rexroth AG 71
/108
Product description
ENGLISH
The maximum torque at the
bolted connections of the termi-
nals at XDN1 must not exceed
0.3 Nm.
CAUTION
Risk of damage to persons and
property!
The user is obliged to maintain the
system-specific requirements for an
emergency OFF system.
When using external power supply
contactors in superior emergency
OFF circuits, observe the restarting
time of 10 seconds for single switch-
ing and 30 seconds for repeated
switching.
Check that the emergency OFF cir-
cuit is functioning correctly before
commissioning the tightening system.
Observe the local, system-specific
regulations and requirements; proper
use of tools, lifting, and transport
equipment; as well as the relevant
standards, provisions, and accident
prevention regulations.
CAUTION
Risk of damage to persons and prop-
erty!
Dangerous shock currents due to insuffi-
cient PE wire connections!
Protective conductor connections
may not be affected by mechanical,
chemical, or electrochemical influ-
ences. The connection must be per-
manent.
NOTE
The voltage circuits on terminal XDN1
are safely isolated from the power
supply circuits (safe isolation in accor-
dance with EN50178). The require-
ments for safe isolation of electric cir-
cuits must be observed if using the
connection options on this terminal.
CS351_zweispaltig - D.book Seite 71 Dienstag, 16. Juli 2013 12:00 12