76
/108
Bosch Rexroth AG CS351/CC-CS351
| 3 609 929 B45/2013-06
Product description
Slot for the mass storage (X6C1)
This interface is intended for the use of the
CF350 mass storage.
USB host interfaces (X3U1, X3U2)
These interfaces are designed as type A
sockets. They meet the requirements accord-
ing to USB Specification 2.0.
Fig. 14: USB socket, type A
NOTE
Damage due to improper assembly!
Damage to the connections
Only use mass storage from Rexroth.
Insert the CF350 mass storage into
the Compact System with the plug-in
connections facing the front, so the
“Rexroth” product label (front side of
the card) is visible.
When installed, the mass storage will
protrude approximately 1.5 cm from
the device. Only push it in until it no-
ticeably catches in the slot.
NOTE
Damage caused by disconnecting
the mass storage while under volt-
age!
Damage to the mass storage
Only disconnect the mass storage
when the Compact System is not un-
der voltage.
Table 9: X3U1, X3U2 assignment
Pin Signal
Description/
function
Voltage/
current
1 VCC 5 V supply 5 V= / 0.5
A
2
USB_Data–
Receive USB
data
3
USB_Data+
Receive USB
data
4 GND Reference po-
tential for all volt-
ages
PE poten-
tial
1234
CS351_zweispaltig - D.book Seite 76 Dienstag, 16. Juli 2013 12:00 12