92
/108
Bosch Rexroth AG CS351/CC-CS351
| 3 609 929 B45/2013-06
Operation
8 Operation
Securing the Compact System
The lock on the front cover can be secured
with a padlock.
LED indicators of the Compact System
Fig. 34: LEDs on the front
CAUTION
Disconnecting plug connectors that
are under voltage!
Damages to the compact system
Always switch the system off at the
main switch and then disconnect the
power supply connection cable. Wait
until the discharging time (at least 90
seconds) has elapsed.
CAUTION
Contamination of the Compact Sys-
tem!
Injuries and damage to property
Only operate the Compact System
with the front cover closed.
CAUTION
Hot surfaces!
Injuries
The metal surfaces of the housing may
have a temperature of up to 70 °C
during operation.
NOTE
Important operation information
Keep the air ways used for cooling
the Compact System clear.
The Compact System may only be op-
erated in grounded networks. Opera-
tion in networks that are not directly
grounded (IT network) is not permit-
ted, as clearance and creepage dis-
tances in the system may be over-
loaded, impairing the function of the
installed residual-current-operated
protective device (only for ErgoSpin
variants).
Solely permissible protective measure
in accordance with EN 50 178: pro-
tective grounding. The inlet cable to
the Compact System must have a PE
wire.
To ensure potential equalization of all
system components, a potential
equalizer is required between the
workpiece and tightening spindle (or
its carrier plate), in addition to ground-
ing the Compact System.
CS351_zweispaltig - D.book Seite 92 Dienstag, 16. Juli 2013 12:00 12