CS351/CC-CS351 Bosch Rexroth AG 61
/108
General safety instructions
ENGLISH
Only operate the Compact System in
grounded networks. Operation in non-
grounded networks (IT network) is not per-
mitted, as clearance and creepage distances
in the system may be overloaded.
Here, protective grounding is the permissible
protective measure in accordance with
EN 50178. The inlet cable to the Compact
System must have a PE wire.
Make sure that there is potential equalization
between the workpiece and tightening spin-
dle, as well as its carrier plate, so that poten-
tial equalization is ensured for all system com-
ponents.
Protect the system from short circuits in the
connector cables with a fuse provided by the
customer.
After switching the device off, wait 10 sec-
onds before turning it back on.
Observe the discharging time (at least 90
seconds after separating the system from the
network) before working on the power supply
connections.
During cleaning
Cover all openings with the appropriate pro-
tective equipment in order to prevent deter-
gents from penetrating the system.
Never use solvents or aggressive detergents.
Only clean the product using a slightly damp,
lint-free cloth. Only use water to do this and,
if necessary, a mild detergent.
Do not use a high-pressure cleaner for clean-
ing.
During maintenance and repair
Perform the prescribed maintenance work at
the intervals specified in the instruction man-
ual.
Make sure that no lines, connectors or com-
ponents are disconnected as long as the sys-
tem is under pressure and voltage. Protect
the system against being switched on.
DANGER
Insufficient emergency OFF equip-
ment!
Danger to life through electrical or me-
chanical forces
The user is responsible for determin-
ing the necessity of an emergency
OFF, its implementation, and the risk
analysis! Make sure the emergency
OFF equipment is accessible and ef-
fective. Release of the emergency
OFF equipment may not result in an
uncontrolled system restart!
Check the function of the emergency
OFF equipment before switching the
system on.