3 Ratings and Dimensions
UL Ratings and Dimensions
Description Symbol Unit HCS03.1E-
W0070-_-05
HCS03.1E-
W0100-_-05
HCS03.1E-
W0150-_-05
HCS03.1E-
W0210-_-05
Listing according to UL standard
(UL)
UL 508 C
Listing according to CSA standard
(UL)
Canadian National Standard(s) C22.2 No. 14-10
UL files (UL) E 227957
Pollution degree (UL) 2
Ambient temperature with nominal
data (UL)
T
amax
°C 40
Ambient temperature with reduced
nominal data (UL)
T
amax_red
°C 55
Mass m kg 13,00 20,00 38,00
Device height (UL)
1)
H mm 490
Device depth (UL)
2)
T mm 262
Device width (UL)
3)
B mm 125 225 350
Minimum distance on the top of the
device
4)
d
top
mm 80
Minimum distance on the bottom of
the device
5)
d
bot
mm 100
Horizontal spacing on the device
6)
d
hor
mm 0
Rated control voltage input (UL)
7)
U
N3
V 24 ± 20 %
Rated power consumption control
voltage input at U
N3
(UL)
8)
P
N3
W 22 25 30
Short circuit current rating (UL) SCCR A rms 42000
Rated input voltage, power (UL)
9)
U
LN_nenn
V 3 x AC 400...500
Tolerance rated input voltage (UL) % +10 -15
Input frequency (UL) f
LN
Hz 50...60
Tolerance input frequency (UL) Hz ± 2
Rated input current (UL) I
LN
A 50,0 80,0 106,0 146,0
Branch circuit protection fuse (UL)
10)
70 100 125 175
Required wire size according to
EN 60204‑1
11)
A
LN
mm
2
16 35 50 70
Required wire size according to UL
508 A (internal wiring); (UL)
12)
A
LN
AWG AWG 8 AWG 4 AWG 2 AWG 1/0
Field wiring material (material; con‐
ductor temperature; class)
Cu; 60/75 °C; 1
Last modification: 2010-08-04
DOK-INDRV*-HCS03******-IT01-EN-P
Rexroth IndraDrive Drive Controllers Power Sections HCS03
Bosch Rexroth AG 23/67
Ratings and Dimensions