DANGER
a. Do Not open or remove the cover while power is on or during the operation. Do
close up the cover before powering on the drive. Do Not remove the cover except
for wiring or periodic inspection when power off.
b. At the function F_051=0, F_078=1, the drive will automatically restart when the
power is restored. Stay away from the motor and machine.
c. At the function F_003=0 and F_001=0 or 1, the
OFF
RESET
key on keypad is ineffective.
Please use an emergency stop switch separately for safe operations.
d. The drive can produce high frequency outputs. Before adjusting the frequency,
please check the specifications of motor carefully to prevent the motor from
unexpected damages.
e. If any of the protective functions have been activated, and the start command is
set to terminal control (F_001=0 or 1). First remove the case and check if the all
running commands set to OFF. Then press the
key to release the alarm.
CAUTION
a. Do Not touch the heat sink or brake resistors due to the high heat.
b. Some models attach nylon rope when shipping. Do Not proceed the movement
or hanging the drive by this nylon rope to avoid unexpecting accident. Please
select a suitable rope to proceed the movement or hanging the drive.