10 August, 2001 SERVICE PROGRAM MODE
4-7
Service
Tables
1
Mode Number/Name Function/[Setting]
By-pass Paper Size Display007
Displays the by-pass paper width sensor output.
Fusing Idling103
Switches fusing idling on/off.
Switch on if fusing on the 1st and 2nd copies is
incomplete (this may occur if the room is cold.)
[1 = On / 0 = Off]
Fusing Temperature Adjustment
1 Roller Center
2 Roller Ends
Adjusts the fusing temperature at the center and both
ends of the hot roller for normal printing.
[120 ~ 200 / 165 / 1°C/step]
3 Energy Saver Adjusts the fusing temperature at the center and both
ends of the hot roller for energy saver mode.
[0 ~ 160 / 150 / 1°C/step]
4 Thick Paper (Center)
5 Thick Paper (Ends)
Adjusts the additional fusing temperature for thick
paper for the 2nd paper tray and for the bypass tray.
[0 ~ 160 / 20 / 1°C/step]
6 After Warming-up
(Center)
Adjusts the fusing temperature at the center of the hot
roller after the machine has warmed up.
[120 ~ 220 / 165 / 1°C/step]
7 After Warming-up
(Ends)
Adjusts the fusing temperature at both ends of the hot
roller after the machine has warmed up.
[120 ~ 220 / 175 / 1°C/step]
8 Number of Pages
In this machine, fusing temperature is kept 10°C higher
than the normal temperature for a number of pages
after the machine has warmed up. This SP selects the
number of pages made at this temperature. See
Detailed Section Descriptions – Fusing for more
details.
[0 ~ 10 / 3 / 1 page/step]
105*
9Times
In this machine, fusing temperature is kept 10°C higher
than the normal temperature for a short while after the
machine been warmed up. This SP selects the length
of time that this temperature is used. See Detailed
Section Descriptions – Fusing for more details.
[0 ~ 180 / 60 / 1s/step]
Fusing Temp. Display
1 Roller Center
2 Roller Ends
Displays the fusing temperature for the center or both
ends of the hot roller.
106
3
In the Machine at Power
On
Displays the temperature in the machine at power on.
This temperature is monitored by the thermistor on the
SBCU board.
Fusing Soft Start Setting108*
1 Selects whether the fusing temperature control cycle is
1 or 3 seconds.
If this is “1 (3 s)”, the power supply fluctuation caused
by the fusing lamp turning on is less often.
[0 = 1 s / 1 = 3 s]
Default: 0 = N. America, 1 = Europe/Asia