10 August, 2001 BRIDGE UNIT INSTALLATION
3-33
3.11 BRIDGE UNIT INSTALLATION
3.11.1 ACCESSORY CHECK
Check the quantity and condition of the accessories against the following list.
No. Description Q’ty
1 Bridge Unit 1
2 Securing Plate 1
3 Shoulder Screw 1
4 Knob Screw 1
3.11.2 INSTALLATION PROCEDURE
- For A265 and A267 copiers -
!
CAUTION
Unplug the copier power cord before starting the following procedure.
1. Remove all tapes.
2. Loosen the screw [A] and remove the front right cover [B].
3. If the sensor feeler [C] is out, fold it away into the machine.
B417I101.WMF
B417I500.WMF
B417I501.WMF
1
2
3
4
[C]
[B]
[A]