EasyManua.ls Logo

Ricoh Aficio 1027 - Toner Supply Motor on Time Determinations

Ricoh Aficio 1027
313 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DEVELOPMENT 10 August, 2001
2-40
Toner Supply Motor On Time Determinations
For fixed control mode, the toner supply motor on time is specified by the setting of
SP2-925, and does not vary. The default setting is 200 ms for each copy. The
toner supply motor on time for each value of SP2-925 is as follows.
Value of SP2-925 Motor On Time (t = 200 ms)
0t
12t
24t
38t
4 12t
5 16t
6 Continuously
7 Not supplied
For sensor control modes 1 and 2, the toner supply motor on time is decided by the
following factors.
Vt (= Vt – (Vref or Vts))
TD sensor sensitivity (coefficient: S, value is 0.3)
There are seven levels for toner supply motor on time as shown below.
Level Decision Motor On Time (seconds)
1
0 < Vt S/16
t (0.6)
2
S/16 < Vt S/8
t x 2 (1.2)
3
S/8 < Vt S/4
t x 4 (2.4)
4
S/4 < Vt S/2
t x 8 (4.8)
5
S/2 < Vt 4S/5
t x 16 (9.6)
6
4S/5 < Vt S (near-end)
T (30); see note 3
7
S < Vt (toner end)
T (30); see note 3
NOTE: 1) The value of “t” can be changed using SP2-922 (default: 0.6 second)
2) The value of “T” can be changed using SP2-923 (default: 30 seconds)
3) T (30) means that toner is supplied intermittently in a half duty cycle
(1.5 s on, 1.5 s off) for 30 seconds