10 August, 2001 COPY ADJUSTMENTS: PRINTING/SCANNING
6-39
Replacement
Adjustment
6.8.2 SCANNING
NOTE: 1) Before doing the following scanner adjustments, perform or check the
printing registration/side-to-side adjustment and the blank margin
adjustment.
2) Use an S5S test chart to perform the following adjustments.
Registration: Platen Mode
1. Place the test chart on the exposure glass and make a copy from one of the
feed stations.
2. Check the leading edge and side-to-side registration, and adjust them using the
following SP modes if necessary.
SP mode
Leading Edge SP4-010
Side-to-side SP4-011
A: Leading Edge Registration
B: Side-to-side Registration
Magnification
NOTE: Use an S5S test chart to perform the following adjustment.
A: Sub Scan Magnification
B: Main Scan magnification
1. Place the test chart on the exposure glass and make a copy from one of the
feed stations.
2. Check the magnification ratio, and adjust it using the following SP mode if
necessary. The specification is ±1%.
SP mode
Sub Scan Magnification SP4-009
Main Scan Magnification SP4-008
_
^
B027R511.WMF
A
B
B027R500.WMF