Bit Switches
SM 111 D361
Fax Option
Type 3350
D361
G3 Switch 0F (SP No. 1-105-016)
No Function Comments
0: Disabled
1: Enabled
1
Alarm when the handset is
off-hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
2-7 Not used Do not change the settings.
4.3.6 G3-2 AND G3-3 SWITCHES
These switches require an optional G3 interface unit.
G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00 (SP No. 1-106-001)
No Function Comments
Monitor speaker during
communication (tx and rx)
Bit 1 Bit 0 Setting
0 0 Disable
0 1 Up to Phase B
1 0 All the time
1 1 Not used
0
1
(0, 0): The monitor speaker is disabled all
through the communication.
(0, 1): The monitor speaker is on up to
phase B in the T.30 protocol.
(1, 0): Used for testing. The monitor
speaker is on all through the
communication. Make sure that you reset
these bits after testing.
2
Monitor speaker during memory
transmission
1: The monitor speaker is enabled during
memory transmission.