B140 SERIES AND G126 SERVICE MODE
SM 4-49 B064 Series/B140 Series/G126
Trouble-
shooting
SC No. Symptom Possible Cause
One of the following occurred:
After power on, or after closing
the front door, the hot roller does
not reach the 100°C control
temperature within 25 s.
5 sec. after temperature rise
started, temperature remained
below 21°C after 5 samplings.
Fusing unit did not attain reload
temperature within 48 sec. of the
start of fusing temperature
control.
Fusing lamp disconnected
Thermistor warped, out of position
Thermostat not operating
Fusing lamp overheat error 1 (software) 543 A
Central thermistor detected a
temperature of 240°C at the center
of the hot roller. Fusing temperature
control software error
PSU defective
IOB defective
BICU defective
Fusing lamp overheat error 1 (hardware) 544 A
Either the central thermistor or an
end thermistor detected a
temperature of 250°C on the hot
roller.
-or-
Fusing temperature control
software error
PSU defective
IOB defective
BICU defective
Fusing lamp overheat error 2 545 A
After hot roller reaches warmup
temperature, the fusing lamps
remained on at full capacity for 11
samplings (1.8 sec. duration) while
the hot roller was not rotating.
Thermistor damaged, or out of position
Fusing lamp disconnected
Zero cross signal malfunction 547 D
One of the following conditions is
detected 10 times:
When the main switch is on, the
frequency measured by the
number of zero cross signals for
500 ms is larger than 66Hz or
smaller than 45 Hz.
The interval between one zero
cross signal and the next is 7.5
ms or shorter 3 times
consecutively for 500 ms.
Noise on the ac power line
Fusing Web End 550 A
Web end detected 5 times within
500 ms and web motor continues to
rotate 40 s. If web end is detected
for another 400 ms, then the SC is
logged.
Web end (requires replacement)
Web end sensor defective
Note: After replacing the web with a new
one, reset SP1902 001 to 0 to
release SC550.
551 A Fusing thermistor error 1