B140 SERIES AND G126 SERVICE MODE
B064 Series/B140 Series/G126 4-48 SM
SC No. Symptom Possible Cause
LCT tray malfunction 510 B
One of the following conditions is
detected:
When the bottom plate is lifted,
the upper limit sensor does not
come on for 18 s.
When the bottom plate is
lowered, the lower limit sensor
does not come on for 18 s.
After lift begins, the upper limit
sensor does not switch on before
the pick-up solenoid switches on.
The paper end sensor switches
on during lift and the upper limit
sensor does not switch on for 2.5
s, and a message prompts user
to reset paper.
Tray lift motor defective or connector
disconnected
Lift sensor defective or disconnected
Pick-up solenoid defective or
disconnected
Paper end sensor defective
Tandem rear fence motor error 515 B
One of the conditions is detected:
The return sensor does not
switch on within 10 sec. after the
rear fence motor switches on.
The HP sensor does not switch
on 10 sec. after the rear fence
motor switches on.
The HP sensor and return sensor
switch on at the same time.
Rear fence motor defective or poor
connection
Paper or other obstacle interfering with
operation of the sensors
Paper or other obstacle trapped between
tray and motor
Motor mechanical overload due to
obstruction
Return sensor or HP sensor defective or
dirty
Duplex jogger motor error 1 520 C
When the jogger fence moves to
the home position, the jogger HP
sensor does not turn on even if the
jogger fence motor has moved the
jogger fence 153.5 mm.
Paper or other obstacle has jammed
mechanism
Sensor connector disconnected or
defective
Sensor defective
Duplex jogger motor error 2 521 C
When the jogger fence moves from
the home position, the jogger fence
HP sensor does not turn off even if
the jogger motor has moved the
jogger fence 153.5 mm.
Paper or other obstacle has jammed
mechanism
Sensor connector disconnected or
defective
Sensor defective
Fusing exit motor error 531 D
The PLL lock signal was low for 2
seconds during motor operation.
Motor lock caused by too much load
Motor driver defective
Fusing thermistor open 541 A
The fusing temperature detected by
the center thermistor was below
0°C for 7 sec.
Thermistor open
Thermistor connector defective
Thermistor damaged, or out of position
Fusing temperature –15% less than the
standard input voltage
542 A Fusing temperature warm-up error

Table of Contents