EasyManua.ls Logo

Ricoh B064 - Page 433

Ricoh B064
1060 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE PROGRAM MODE TABLES
SM 5-31 B064 Series/B140 Series/G126
Service
Tables
1103* Fusing Idling (B064 only)
This setting controls the length of time that the hot roller turns freely with no paper
in the fusing unit. This increases the temperature of the hot roller.
Adjusts the fusing idling time:
[0~900/1 s]
Increase this value when fusing on the 1st and 2nd copies is not completed
because of low room temperature.
1104* Fusing Temperature Control
Selects the fusing temperature control mode.
[0~1/1]
0: On/Off control
1: Phase control
If power supply to the machine is unstable, select Phase Control. The machine
must be switched off and on after this setting is changed for the new setting to take
effect.
Phase control could interfere with radio or TV reception.
1105* Fusing Temperature Adjustment
Adjusts the fusing temperature of the hot roller for plain paper, OHP or thick paper.
001
Normal Time (Center
Thermistor)
Fusing temperature during the ready condition (and
during printing for B064)
B064: [150~230/1 degree C]
B140: [180~205/1 degree C]
002
Normal Time (End
Thermistors) (B140 Only)
Fusing temperature during the ready condition
B140: [180~205/1 degree C]
003 OHP (Center Thermistor)
Fusing temperature during printing:
B064: [150~230/1 degree C]
B140: [180~205/1 degree C]
004
OHP (End Thermistor)
(B140 Only)
Fusing temperature during printing:
B140: [180~205/1 degree C]
005
Thick Paper (Center
Thermistor)
Fusing temperature during printing:
B064: [180~205/1 degree C]
B140: [180~205/1 degree C]
006
Thick Paper (End
Thermistors) (B140 Only)
Fusing temperature during printing:
B140: [180~205/1 degree C]
007
Normal Paper (Center
Thermistor) (B140 Only)
Fusing temperature during printing:
B140: [150~230/1 degree C]
008
Normal Paper (End
Thermistor) (B140 Only)
Fusing temperature during printing:
B140: [180~205/1 degree C]
1106 Fusing Temperature Display
001 Center Temperature
Shows the temperature of the hot roller detected by the
thermistor at the center of the hot roller.
002 End Temperature
Shows the temperature of the hot roller detected by the
thermistors at the ends of the hot roller.

Table of Contents