[Machine: Maintenance]
0501 [Execute Cleaning Initial Setting for PCU]
Execute after replacement of photoconductor cleaning unit and drum. When the counter is cleared, this
is automatically executed, so it is not necessary to execute this manually. Do not open the front left cover
or front right cover while executing [Execute Cleaning Initial Setting for PCU]. The control panel shows
information during the operation.
• If it is necessary to execute this for all colors, execute it in the order of [CMY] and [Black].
Setting Items Remarks
[CMY] Press [Execute].
[Black]
[Cyan]
[Magenta]
[Yellow]
Setting Item
Default
Value
Max.
Value
Min.
Value
Step Unit
[Number of Pattern Repeats] 7 16 0 1 Times
0502 [Wind Fuser Cleaning Unit at Replacement]
Wind Fusing Cleaning Web.
Setting Item Remarks
[Execute] Press [Execute].
0503 [Temperature/Humidity Inside]
Display temperature and humidity inside the machine.
2. Details of Menu Items in Adjustment Settings for Skilled Operators
16