0511 [Smooth Fusing Belt]
Smooth the Fusing Belt.
Setting Items Remarks
[Belt Scratches] Press [Execute].
[Uneven Gloss (Short Time)]
0512 [Fusing Belt Smoothing Execution Time]
Set the duration for Fusing Belt smoothing.
Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[Belt Scratches] 150 3600 0 5 sec
[Uneven Gloss (Short Time)] 3 60 1
0513 [Fusing Belt Smoothing Setting (Set by User)]
Set interval and duration when [Automatic Execution: Set by User] is selected at [Auto Execute Belt
Smoothing: For Belt Scratches] in [Fusing Belt Smoothing Setting] for Custom Paper.
Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
[Number of Sheets per Interval] 500.00 600000.
00
0 0.01 page
[Execution Time] 60 360 10 sec
0514 [Manage Multiple Fusing Units by Counter]
Display the counter of Fusing Unit parts.
2. Details of Menu Items in Adjustment Settings for Skilled Operators
20