Setting Items Remarks
[PCU 1 Temperature] Value display only.
[PCU 1 Humidity]
[PCU 2 Temperature]
[PCU 2 Humidity]
0504 [Temperature/Humidity Outside]
Display temperature and humidity around the machine.
Setting Items Remarks
[Temperature] Value display only.
[Humidity]
0505 [Screw-on Cap to Replace]
Close the toner bottle cap.
The toner bottle in use can be pulled out when the cap is closed. Use the function when you want to
remove the toner bottle in use, or to replace the bottle with a new bottle.
Make sure that the toner bottle cover (the cover of the toner dispensing section) is closed when you
perform this. After performing this, open the cover and then, pressing the release lever under the
toner bottle, remove the toner bottle.
[Machine: Maintenance]