Chapter 2 Basic Waveform Output RIGOL
DG4000 Series Users Guide
2-13
To Set Parameters for Pulse
To output a pulse, users need to set the Pulse Width/Duty Cycle, Leading edge,
Trailing edge, Delay and Recover Delay in addition to the basic parameters
(such as frequency, amplitude, DC offset voltage, start phase, high level, low level
and align phase) introduced above.
Pulse Width/Duty Cycle
Pulse Width is defined as the time from the 50% threshold of a rising edge
amplitude to the 50% threshold of the next falling edge amplitude as shown in the
figure above.
Pulse Width range is limited by the Minimum Pulse Widthand the Pulse
Period (for the ranges of Minumum Pulse Width and Pulse Period, please
refer to Signal Characteristics in Specifications). The default value is 500μs.
Pulse Width Minimum Pulse Width
Pulse Width Pulse Period - Minimum Pulse Width × 2
Pulse Duty Cycle is defined as the percentage that the Pulse Width takes up in the
whole period.
脉宽
10%
t
Rise
t
Fall
90%
50%
Pulse Period
Pulse Width