Chapter 6 MATH and Measurements RIGOL
MSO2000A/DS2000A Users Guide 6-19
Delay and Phase
Figure 6-4 Delay and Phase
Source A and source B can be CH1, CH2 or any of D0 to D15. You can set them via
Measure Setting Type “Delay” (“Phase”). For the setting method, refer to
Measurement Setting”.
1. Dly A B : the time difference between the threshold middle values of the
rising edges of source A and source B.
2. Dly A
B : the time difference between the threshold middle values of the
falling edges of source A and source B.
3. Dly A
B : the time difference between the threshold middle values of the
rising edge of source A and the falling edge of source B.
4. Dly A
B : the time difference between the threshold middle values of the
falling edge of source A and the rising edge of source B.
5. Phs A
B : the phase difference between the threshold middle values of the
rising edges of source A and source B. It can be calculated according to Dly
A
B and the period of source A.
6. Phs A
B : the phase difference between the threshold middle values of the
falling edges of source A and source B. It can be calculated according to Dly
A
B and the period of source A.
7. Phs A
B : the phase difference between the threshold middle values of the
rising edge of source A and the falling edge of source B. It can be calculated
according to Dly A
B and the period of source A.
8. Phs A
B : the phase difference between the threshold middle values of the
falling edge of source A and the rising edge of source B. It can be calculated
according to Dly A
B and the period of source A.
Period
Delay
Source A
Source B