Chapter 11 Waveform Record    RIGOL 
MSO2000A/DS2000A User’s Guide  11-11 
(refer to the setting method of the current frame mentioned above) and the 
default is the first frame.  
  End Frame: press this key to set the end frame of waveform analysis (refer 
to the setting method of the current frame mentioned above) and the 
default is the last frame.  
  Threshold: press this key to set the threshold of waveform analysis and the 
range is from 1% to 99%. The threshold is used to judge whether the frame 
is an error frame. A frame is recognize as an error one if the (relative) 
difference value between the frame and the templet is equal to or larger 
than the threshold currently set. 
 
9.  Time Tag 
The time tag is used to display the absolute recording time of each frame of the 
waveform currently recorded. Press Time Tag to enable or disable the time tag 
function. When it is enabled, the time tag information is displayed at the upper 
right corner of the screen as shown in the figure below. 
 
T
0
:
 
display the absolute starting time of the waveform record.  
△T: display the recording time deviation of the current waveform relative to the 
first frame of waveform.  
 
www.GlobalTestSupply.com