Rinstrum - 5200 Communications Manual Rev 1.2
Page 12 0025-605-120
2.4.3. ASF: Set Filtering
This is used to set the filtering characteristics of an instrument.
General Details
No. of Parameters Save Changes Changes Used Increment Trade Counter
2 With TDD1 On TDD1 No
Parameter Details
Parameter Description Range Default Required
1 Number of
consecutive
readings to
average
0
9
10
11
12
13
14
1
10
25
50
75
100
200
9 No
2 Anti-Jitter
Setting
0
1
2
Off
Fine
Course
0 No
Example
Command Response Details
S01; Select Instrument 1
ASF?; 10,00,00 CRLF Query Filtering Setting
ASF4,1; 0 CRLF Changed to a 5 reading average with fine
anti-jitter filtering
TDD1; 0 CRLF Save New Settings