2.4.12. ENU: Set Units
Sets the units of weight to be displayed and printed.
General Details
No. of Parameters Save Changes Changes Used Increment Trade Counter
1 With TDD1 Immediately Yes
Parameter Details
Parameter Description Range Default Required
1 Weight units 0
1
2
3
4
none
g
kg
lb
t
2 No
Example
Command Response Details
S01; Select Instrument 1
ENU?; 2 CRLF Query units
ENU1; 0 CRLF Change units to grams
TDD1; 0 CRLF Save new setting