Rinstrum - 5200 Communications Manual Rev 1.2
Page 48 0025-605-120
2.4.36. Sxx: Select Instrument
This is used to select one or more instruments with which to communicate.
General Details
No. of Parameters Save Changes Changes Used Increment Trade Counter
Special case - - No
xx Range Options
xx Range Operation Use
00 to 31 Select a single instrument with the
matching address 00 to 31. All
other instruments are de-selected.
Communication with single
instrument.
96 De-select all instruments.
97 to 98 All instruments will execute
commands but none will respond.
Network blanket command
without reply.
99 All instruments are selected and
will respond. Reply contention
problems if more than one
instrument is on the network.
Only a single instrument (possibly
of unknown address) is present
on the network.
Example
Command Response Details
S01; Select Instrument 1
MSV?; ^^^400.0 CRLF Query Current Weight
S02; Select Instrument 2
MSV?; ^^^623.5 CRLF Query Current Weight
S96; De-Select All Instruments