Address Parameter Description
4) If password lock is present & to modify 4X parameter
rst send valid password to this location so that 4X parameter
will be accessible for modication.
5) If for in any of the above case invalid password is send then
meter will return exceptional error 2.
This address is used to set the Conguration for relay 2
see table 8 . Writting any other value will return an error.
40073
Limit1
Conguration
Select
40079
30mA Noise
current
Elimination
Limit2
Conguration
Select
This address is used to set the Conguration for relay 1
see table 8 . Writting any other value will return an error.
This address is used to activate or de-activate the 30 mA noise
current elimination write
0-Deactivate
30 (Decimal)-Activate
Writing any other value will return an error.
40075
40081
Energy
Update
Rate
Energy Update Rate is the time after which energy registers
are updated. This time is user settable from 1 - 60 minutes.
40083
This Address is Read Only. This Address shows the Model
Number of the meter
Model
Number
40077
Auto
Scroll
This address is used to activate or de-activate the Auto Scroll
Setting
0-Deactivate
1 (Decimal)-Activate
Writing any other value will return an error.