sACN Priority - The value of this item can be set in range 0-255.
Discovery Settings - the menu item allows you to set a behaviour of the RoboSpot during RDM discovery
process (menu item RDM Discovery) and after switching the RoboSpot on.
Auto - the RoboSpot searches connected devices after each switching it on and does not save
the list of discovered devices. Also If the option RDM Discovery is run, the list of discovered devices
is not saved.
Manual - the RoboSpot searches connected devices and save the list of discovered devices.
When the RoboSpot is switched on, the saved list of discovered devices will be load to the RoboSpot
and (even in case that xtures are not be connected to RoboSpot) the RoboSpot will not run
the discovery procedure.
Controls invert - the menu item allows you to invert pan/tilt and faders of the RoboSpot.
Default settings of faders: fader down-minimum (0 DMX), fader up-maximum (255 DMX).
Faders Switch - swaps functions of faders.
Camera Rotation - the function rotates a camera picture on the monitor 180 degrees from the current orientation.
Camera Zoom invert - the function inverts a camera zoom.
Shutter Pass On - the function has inuence on behaviour of shutters of connected xtures.
O - After switching the RoboSpot on, shutters will be closed until you activate the FollowSpot Controller
(by pressing the button ACTIVE). After its activating, xtures can receive DMX values for shutters
from control desk.
On - After switching the RoboSpot on, shutters can be controlled from the desk without activating
the FollowSpot Controller.
Ctrl.On When PWR On - if the function is on, the Pan/Tilt buttons of the FollowSpot Controller are auto-
matically activated after connecting power to the FollowSpot Controller.
Password Settings - the menu item allows you to change the password or switch it on/o at entry the FollowSpot
Controller menu. The password applies to the FollowSpot Controller as well as to the RoboSpot 15.6" screen.
Change password - use this option to change password. Default (factory) password is 5242.
Protect with Password - If this function is on, the password is required at entry the FollowSpot
Controller menu.
Note: both menu items stated above require inserting of password to enter them even the password is
set o ! You have to remember the last set password!
In case you have forgotten your password, use the master password 4678.
Recalibrate Touchscreen - the item starts calibration of the touchscreen. Follow instructions on
the screen.
Default Settings - The menu item allows you to set the items stated above (except Ethernet Settings) to default
values.
Note: the password will not be set to a default password (set password will remain without change) but the
option Protect with Password will be set to On.
7. Software update
RoboSpot software update is done via a network connection between a computer running a ROBE RDM Up-
loader software through the CAMERA input (RJ45) of the RoboSpot base station. It is important to note, that
computer IPv4 address has to be set to 10.x.x.x network (for example 10.0.1.10) with netmask 255.0.0.0 .
During the update, the FollowSpot Controller has to be attached to the RoboSpot.
Do note, that to enable all new features, you must update the RoboSpot base station and also all BMFL xtures