11-5-2
ENGINE SPEED
IS
NOT REDUCED WHEN LOAD
IS
OFF.
(1) Check the distortion of the SOLENOID BRACKET as shown in step 11-5-1-(1).
(2)
Check the wiring of SOLENOID.
Check
two
leads from SOLENOID are securely connected.
(3)
Check the wiring of IDLE CONTROL UNIT.
Check all leads from IDLE CONTROL UNIT are securely and correctly connected.
(4)
Checking the SOLENOID.
Measure the resistance between
two
leads
from SOLENOID.
25-31
Q
If
the resistance is larger or smaller than this range,
SOLENOID is defective,
Replace with
a
new one.
SOLENOID
\
Fig-
11-17
-9
-
60-