15
Lower Leg Removal and Service
Lower Leg Removal and Service
50/200 Hour Service Lower Leg Removal
ZEB is pictured in this section. Procedures are the same for Lyrik and Pike unless otherwise described.
Remove the air valve cap.Remove the air valve cap.
Depress the Schrader valve and release all air pressure.Depress the Schrader valve and release all air pressure.
⚠ CAUTION - EYE HAZARD
Verify all pressure is removed from the fork before proceeding.
Failure to do so can result in injury and/or damage to the fork. Wear
safety glasses.
Turn the rebound adjuster knob counter-clockwise until it stops. This is Turn the rebound adjuster knob counter-clockwise until it stops. This is
the full open/fast rebound setting.the full open/fast rebound setting.
Loosen the set screw and remove the rebound damper adjuster knob.Loosen the set screw and remove the rebound damper adjuster knob.
1
2
3
Counter-clockwise Rebound - Full Open Setting
4
2.5 mm