EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 5100 - Page 103

Rockwell Automation Allen-Bradley Kinetix 5100
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication KNX-SG001H-EN-P - December 2020 103
Kinetix 5500 Servo Drives
Performance Specifications with 200V-class Drive Operation and Frame 150 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient temperature and rated line
voltage. For additional information on ambient temperature and line conditions, refer to Motion Analyzer.
Performance Specifications with 400V-class Drive Operation and Frame 30 Linear Thrusters
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient temperature and rated line
voltage. For additional information on ambient temperature and line conditions, refer to Motion Analyzer.
Linear Thruster
Cat. No.
Velocity, max
230V AC
m/s
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
A 0-pk
System Peak
Stall Force
N (lb)
Rated Output
230V AC
kW
Kinetix 5500 Drives
(240V AC input)
LDAT-S152010-DDx
…
LDAT-S152090-DDx
1.8 5.3
643 (145)
19.5 1799 (404) 0.87 2198-H025-ERSx
LDAT-S152010-EDx
…
LDAT-S152090-EDx
0.9 2.7 9.8 1679 (377) 0.34 2198-H015-ERSx
LDAT-S153010-DDx
…
LDAT-S153090-DDx
1.8 8.0 978 (220) 29.1 2680 (602) 1.33 2198-H040-ERSx
LDAT-S154010-DDx
…
LDAT-S154090-DDx
1.8 10.7
1306 (294)
39.1 3597 (809) 1.78 2198-H040-ERSx
LDAT-S154010-EDx
…
LDAT-S154090-EDx
0.9 5.3 19.5 3383 (761) 0.70 2198-H025-ERSx
LDAT-S156010-DDx
…
LDAT-S156090-DDx
1.8 16.3
1997 (449)
59.4 5469 (1229) 2.71 2198-H070-ERSx
LDAT-S156010-EDx
…
LDAT-S156090-EDx
0.9 8.1 19.8 5110 (1149) 1.05 2198-H025-ERSx
Linear Thruster
Cat. No.
Velocity, max
460V AC
m/s
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
A 0-pk
System Peak
Stall Force
N (lb)
Rated Output
460V AC
kW
Kinetix 5500 Drives
(480V AC input)
LDAT-S031010-DDx 2.4
4.8 81 (18) 12.2 168 (38)
0.20
2198-H015-ERSx
LDAT-S031020-DDx 3.1 0.25
LDAT-S031030-DDx 3.5 0.29
LDAT-S031040-DDx 3.8 0.31
LDAT-S032010-DDx 3.1
7.4
126 (28)
24.3
336 (76)
0.40
2198-H025-ERSx
LDAT-S032020-DDx 4.1 0.52
LDAT-S032030-DDx 4.7 0.59
LDAT-S032040-DDx 5.0 0.63
LDAT-S032010-EDx 3.1
3.7 12.2
0.40
2198-H015-ERSx
LDAT-S032020-EDx 4.1 0.52
LDAT-S032030-EDx 4.7 0.59
LDAT-S032040-EDx 5.0 0.63
LDAT-S033010-DDx 3.5
11.1
190 (43)
36.5
504 (113)
0.67
2198-H040-ERSx
LDAT-S033020-DDx 4.7 0.88
LDAT-S033030-DDx
5.0 0.95
LDAT-S033040-DDx
LDAT-S033010-EDx 3.5
3.7 12.2
0.67
2198-H015-ERSx
LDAT-S033020-EDx 4.7 0.87
LDAT-S033030-EDx
5.0 0.91
LDAT-S033040-EDx

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Kinetix 5100

Related product manuals