EasyManuals Logo

Rockwell Automation Allen-Bradley PowerFlex 700 User Manual

Rockwell Automation Allen-Bradley PowerFlex 700
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
1-56 Programming and Parameters
INPUTS & OUTPUTS
Analog Outputs
342
345
[Analog Out1 Sel]
[Analog Out2 Sel]
Selects the source of the value that
drives the analog output.
Default:
Options:
0“Output Freq”
See Table
001
002
003
004
005
007
006
012
135
136
137
138
220
219
377
378
343
346
[Analog Out1 Hi]
[Analog Out2 Hi]
Sets the analog output value when the
source value is at maximum.
Default:
Min/Max:
Units:
20.000 mA, 10.000 Volts
4.000/20.000mA
0.000/20.000mA
–/+10.000V
0.001 mA
0.001 Volt
340
342
344
347
[Analog Out1 Lo]
[Analog Out2 Lo]
Sets the analog output value when the
source value is at minimum.
Default:
Min/Max:
Units:
0.000 mA, 0.000 Volts
4.000/20.000mA
0.000/20.000mA
–/+10.000V
0.001 mA
0.001 Volt
340
342
File
Group
No.
Parameter Name & Description
See page 1-2 for symbol descriptions
Values
Related
Vector
* Vector Control Option Only **Vector firmware 3.001 & later
(1)
Refer to Option Definitions on page 1-57.
Options
[Analog Out1 Lo] Value
[Analog Out1 Hi] Value
Param. 341 = Signed Param. 341 = Absolute
0
1
1*
2
3
4
5
6
7
8
9
10
11
12
13
14*
15*
16*
17*
18*
19*
20-23**
24**
“Output Freq”
“Command Freq”
“Command Spd”
“Output Amps”
“Torque Amps”
“Flux Amps”
“Output Power”
“Output Volts”
“DC Bus Volts”
“PI Reference”
(1)
“PI Feedback
“PI Error”
“PI Output”
“%Motor OL
“%Drive OL
“CommandedTrq”
“MtrTrqCurRef
(1)
“Speed Ref
“Speed Fdbk”
“Pulse In Ref
(1)
“Torque Est”
(1)
“Scale Block1-4”
(1)
“Param Cntl”
(1)
–[Maximum Speed]
–[Maximum Speed]
–[Maximum Speed]
0 Amps
–200% Rated
0 Amps
0 kW
0 Volts
0 Volts
–100%
–100%
–100%
–100%
0%
0%
–800% Rated
–200% Rated
–[Maximum Speed]
–[Maximum Speed]
–25200.0 RPM
–800%
0 Hz
0 Hz
0 Hz/RPM
0 Amps
0 Amps
0 Amps
0 kW
0 Volts
0 Volts
0%
0%
0%
0%
0%
0%
0%
0%
0 Hz/RPM
0 Hz/RPM
0 Hz/RPM
0%
+[Maximum Speed]
+[Maximum Speed]
+[Maximum Speed]
200% Rated
200% Rated
200% Rated
200% Rated
120% Rated Input Volts
200% Rated Input Volts
100%
100%
100%
100%
100%
100%
800% Rated
200% Rated
+[Maximum Speed]
+[Maximum Speed]
+[Maximum Speed]
+800%
Vector
Vector
20B-UM001.book Page 56 Thursday, June 20, 2013 1:55 PM

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 700 and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 700 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 700
CategoryDC Drives
LanguageEnglish

Related product manuals