Power Amplifier - Removal and Installation R&S M3SR Series 4100 HF Transceivers
5.17 6124.9007.82.01
Fig. 5.10 Removing Power Amplifier (A30)
1 Screws (8x)
2 Connector X250 (cable W52)
3 Connector X280 (cable W280)
4 Connector X281 (cable W281)
5 Connector X204 (cable W284)
6 Connector X205 (cable W275)
5.7.2 Installation of Power Amplifier (A30)
To install a new or repaired Power Amplifier (A30) proceed as follows:
1. During installation put the cables W52, W275 and W284 into the intended cutout of cable duct.
2. Install the Power Amplifier (A30) in reverse order of removal.
3. Close the R&S M3SR Series 4100 150 W HF Transceiver in reverse order as described in
5.1 - Disassembly.