EasyManua.ls Logo

Rohde & Schwarz M3SR Series 4100 - Function Test with Built-in Tests

Rohde & Schwarz M3SR Series 4100
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Test with Built-in Tests R&S M3SR Series 4100 HF Transceivers
3.3 6124.9007.82.01
3.2 Function Test with Built-in Tests
For operation of the transceiver two failure classes are defined, associated with the following types of
messages:
Warnings:
¾ Operation may go on even if warning messages are displayed.
¾ The radio should be checked as soon as possible.
¾ All active warnings are logged in the failure archive.
Errors:
¾ The radio is no longer in proper working order.
¾ As soon as an error is detected, the LED FAULT lights up.
¾ Error messages remain resident until the fault is eliminated and will be logged in the failure ar-
chive.
Performing Built-in Tests
Carry out the test steps in Table 3.2.
Table 3.2: Built-in Tests
No. Activity Nominal Value
1 PBIT (Power-on Built-In Test)
1.1 Connect a 28 VDC power supply to connector contacts
X31.A1 (+) and X31.A2 (ground).
NOTE:
Note that a 28 VDC supply voltage is available at antenna
connector X30.
Connect a load (50 , > 100 W) to antenna connector X30.
Connect a mating connector to connector X26 with short-cir-
cuit of pins X26.6 and X26.44.
If no R&S GB 4000C Comfort Control Unit is installed, con-
nect one to LAN connector X20. Connect R&S GB 4000C to
transceiver via default address on MMI choosing Connect
and Enter button.