R&S M3SR Series 4100 HF Transceivers Backup Battery - Removal and Installation
6124.9007.82.01 5.30
5.15 Backup Battery - Removal and Installation
5.15.1 Removal of the Backup Battery
NOTE:
To maintain the functional order of the transceiver at all times, a backup battery is included
on the Radio Controller. This battery should be replaced every 3 years.
To remove the Backup Battery from the R&S M3SR Series 4100 150 W HF Transceiver proceed as
follows (see also
Fig. 5.20):
1. Store the configuration data and preset data before removing the Backup Battery.
2. Take off the top cover of the R&S M3SR Series 4100 150 W HF Transceiver as described in
5.1 - Disassembly.
3. Disconnect the old Backup Battery on the Radio Controller (A60).
4. Remove the binders.
5. Take off the old Backup Battery.
CAUTION
Dispose of the battery in compliance with the relevant regulations.
Do not open the battery, since the electrolytic agent is extremely caustic. Allowing
the battery contents to get into the air or water involves risks of inflammation, explo
-
sion and burning.
Do not recharge the battery because of the risk of explosion.
Do not burn the battery and do not allow it to heat up to more than 100 °C.