EasyManua.ls Logo

Rohde & Schwarz R&S SMA100A - Version 2.15.185.13

Rohde & Schwarz R&S SMA100A
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S SMA100A Information on the Current Version and History
Release Notes for Firmware 1171.5360.52 13
No valid DME pulse will be generated, if DME NRP trigger normalization failed due
to missing connection between RF output and R&S® NRP-Z81
Wrong FM deviation, if the DME modulation was active before
DME modulation: Mode “Reply”, Trigger Mode “Ext. Power Sensor”: Trigger does
not work after changing the frequency
DME Modulation: After execution of “Normalize Setup” in DME Analysis the system
will hang for several minutes.
1.13 Version 2.15.185.15
Released: October 2010
Fixed Issues
Adjustment after firmware update is not working due to restrictions in the file
system. This effect could only show up when updating older instruments with rsu-
files. Newer instuments (shipped from mid 2009) are not affected.
Entering new license keys may lead to misleading error messages.
Remote commands *IDN? and *OPT? are not working correctly when code
emulation is active, i.e. SCPI language is not native ("SCPI").
1.14 Version 2.15.185.13
Released: October 2010
New Functionality
Support of new wide screen display (this version is necessary for all SMA with
serial number higher than 103000)
Remote control emulation Agilent E4428 and E4438 (ESG)
Remote control emulation Agilent E8257 and E8267 (PSG)
Remote control emulation Agilent E8663
Remote control emulation Agilent N5161, N5162, N5181, N5182, N5183 (MXG)
Remote control emulation Racal 9087
Remote control emulation Aeroflex 2051/2052
Option R&S® SMA-K28 (Power Analysis): New trigger modes “Internal” and
“External”
Option R&S® SMA-K28 (Power Analysis): User specific level offset
Option R&S® SMA-K28 (Power Analysis): Added mathematical functions and
reference trace