EasyManua.ls Logo

Rohde & Schwarz ZNB40 - Calculate:transform

Rohde & Schwarz ZNB40
1498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
928User Manual 1173.9163.02 ─ 54
Manual operation: See "TD-VSWR" on page 321
8.3.1.20 CALCulate:TRANsform...
The CALCulate:TRANsform... commands convert measured data from one repre-
sentation to another and control the transformation into the time domain (see Chap-
ter 5.7.2, "Time Domain Analysis", on page 203).
CALCulate<Chn>:TRANsform:COMPlex.......................................................................... 928
CALCulate<Chn>:TRANsform:IMPedance:RNORmal........................................................ 929
CALCulate<Chn>:TRANsform:TIME[:TYPE]..................................................................... 929
CALCulate<Chn>:TRANsform:TIME:CENTer.................................................................... 930
CALCulate<Chn>:TRANsform:TIME:DCHebyshev............................................................ 930
CALCulate<Chn>:TRANsform:TIME:LPASs......................................................................931
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam.....................................................931
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:CONTinuous................................. 932
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate................................ 932
CALCulate<Chn>:TRANsform:TIME:LPFRequency........................................................... 933
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor.................................................. 933
CALCulate<Chn>:TRANsform:TIME:SPAN....................................................................... 933
CALCulate<Chn>:TRANsform:TIME:STARt...................................................................... 934
CALCulate<Chn>:TRANsform:TIME:STATe...................................................................... 934
CALCulate<Chn>:TRANsform:TIME:STIMulus..................................................................935
CALCulate<Chn>:TRANsform:TIME:STOP.......................................................................935
CALCulate<Chn>:TRANsform:TIME:WINDow...................................................................935
CALCulate<Chn>:TRANsform:TIME:XAXis.......................................................................936
CALCulate<Chn>:TRANsform:COMPlex <Result>
Converts S-parameters into converted (matched-circuit) Y-parameters or Z-parameters
and vice versa, assuming that port no. i is terminated with Z
0i
so that the three parame-
ter sets are equivalent and the following formulas apply:
ii
ii
iii
S
S
ZZ
1
1
0
,,2
00
00
jiZZ
S
ZZ
Z
ji
ij
ji
ij
ii
ii
ii
i
ii
Z
S
S
Z
Y /1
1
11
0
99...,,1,,,/1
2
0000
jijiZ
ZZSZZ
S
Y
ij
jiijji
ij
ij
SCPI Command Reference

Table of Contents

Related product manuals