Table 1.0 Command ID Data Byte Data Type
Byte details
7 ------- 0
Data Details
$66 (102) = LFO 2 Control 00xxxxxy y = 0=Mode (0=Normal,1=Plus)
xxxxx= 00000-Free Running
00001-Sync Two Notes (192 Clocks/Step)
00010-Sync Dotted Whole Note (144 Clocks/Step)
00011-Sync Whole Note (96 Clocks/Step)
00100-Sync Dotted Half Note (72 Clocks/Step)
00101-Sync Half Note (48 Clocks/Step)
00110-Sync Dotted 1/4 Note (36 Clocks/Step)
00111-Sync Quarter note (24 Clocks/Step)
01000-Sync Dotted 1/8 Note (18 Clocks/Step)
01001-Sync 1/4 Note Triplets (16 Clocks/Step)
01010-Sync 8th note (12 Clocks/Step)
01011-Sync 8th note triplets (8 Clocks/Step)
01100-Sync 16th note (6 Clocks/Step)
01101-Sync 16th note triplets (4 Clocks/Step)
01110-Sync 32nd note (3 Clocks/Step)
01111-Sync 32nd note triplets (2 Clocks/Step)
10000-Sync 64th note triplets (1 Clocks/Step)
Sync source is Master Clock
$67 (103) = LFO 3 Wave 00000xxx xxx = LFO 1 Wave
000=Sine
001=Triangle
010=Square
011=Saw
100=Reverse Saw
101=Random
110=Fast Random
$68 (104) = LFO 3 Rate 0xxxxxxx (0-127)
$69 (105) = LFO 3 Delay 0xxxxxxx (0-127)
www.kiwitechnics.com 3P Matrix Upgrade User Manual v1.2